The first type: Automated manual tin feeding but no tin output?
If this situation occurs, then we need to check whether the tin delivery piece installation adjustment bolts have been adjusted in place?
The fragmented parts of the second type of soldering machine are no longer in place?
1. Check if the power supply is normal;
2. Check if the drive is functioning properly;
3. Check whether the sensor shape is normal;
The third situation: The handheld teaching device has no display. Could it be that it shows only half of the display or has garbled characters?
If this situation occurs, it is first recommended to press f2 on the standby interface to refresh, then check if the connection cable is loose, and then power on again. Before connecting the adapter, make sure there was no power failure before.
The fourth type: Abnormal communication?
1. Check whether the serial port connection cable is damaged;
2. Check whether the equipment has completed the reset measure;
3. During the operation of the automatic soldering machine, only local commands such as "Reset" or "Pause" will be responded to; other commands will not be responded to.
The fifth situation: The power is connected, but the machine is not powered on?
If such a situation occurs, then one needs to stop thinking from the following three aspects. For example:
1: Check if the power switch is turned on;
2: Check if the socket is loose.
3: Check if the fuse has blown.
The sixth type: The device cannot be started?
First, check if the production volume has been completed. For the USB flash drive automatic drag soldering machine, connect the handheld box and you can check. If the production volume has been completed, just reset the soldering machine's production volume to zero.
2. Check if the start button is functioning properly. You can use a handheld box to control the device to start. Use the double soldering iron soldering machine platform to eliminate this problem.
3. Check whether the automated soldering machine equipment has been authorized. When the handheld box is connected and the "Start" button is pressed, a registration dialog box pops up on the screen, indicating that the equipment has not been authorized for use
about
Introduction video case honor partners factoryproduct
Automatic welding line Non-standard customization Automatic soldering Glue/screw lockingnews
dynamic Information faqCustomer Service
contactMr. Xia:+86 186-7696-3763
WeChat QR code
Douyin QR Code
Copyright © 2025 Copyright © Dongguan Chuangxiao Automation Technology Co., Ltd.
本站相关网页素材及相关资源均来源互联网,如有侵权请速告知,我们将会在24小时内删除